The UTD1000C Series handheld oscilloscope offers user-friendliness, outstanding technical indicators and a host of advanced features which can be powered by external AC power supply or powered by built-in lithium batiery. Its powerful trigger and analytical functions also make it easy to acquire and analyses waveforms, while the sharp and clear LCD and mathematics functions ensure clear observation and reliable analysis of signal conditions. It is the perfect tool for completing testing switily and efficiently. As the design is based on the controls of traditional instruments, users can use the new units without spending considerable time in learning and familiarizing with operation.
60MHz/100MHz/200MHz
BANDWIDTH
2
ANALOG CHANNELS
200MSa/s~1GSa/s
REAL-TIME SAMPLE RATE
7.5 kpts
MAX. MEMORY DEPTH
/
WAVEFORM CAPTURE RATE
/
DIGITAL CHANNELS
FEATURES
MODEL
MANUAL
OPTIONS&ACCESSORIES
SOFTWARE&FIRMWARE
VIDEO
FAQS
2 in 1
Oscilloscope & Multimeter
2 in 1
More parameter measurement types
Display cursor peak-to-peak value, amplitude, maximum value, minimum value, top value, bottom value, middle value, average value, rms value, overshoot, preshoot, frequency, period, rise time, fall time during automatic measurement , positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, rise delay, fall delay measurement of a total of 27 kinds
More parameter measurement types
Monochrome display
Single color display can be set, more suitable for outdoor use under strong light
Monochrome display
Fully automatic setup function
Automatic setting function (AUTO SCALE) Vertical and time base gears can be automatically adjusted with signal changes without manual intervention
Fully automatic setup function
Auto configuration
Powerful automatic setting function, fast and accurate automatic setting for signals containing any DC component
Auto configuration
MODEL
UTD1202C
BANDWIDTH:200 MHz
ANALOG CHANNELS:2
REAL-TIME SAMPLE RATE:1 Gsa/s
MAX. MEMORY DEPTH:7.5 kpts
WAVEFORM CAPTURE RATE:-
DIGITAL CHANNELS:-
UTD1102C
BANDWIDTH:100 MHz
ANALOG CHANNELS:2
REAL-TIME SAMPLE RATE:500 Msa/s
MAX. MEMORY DEPTH:7.5 kpts
WAVEFORM CAPTURE RATE:-
DIGITAL CHANNELS:-
UTD1062C
BANDWIDTH:60 MHz
ANALOG CHANNELS:2
REAL-TIME SAMPLE RATE:250 Msa/s
MAX. MEMORY DEPTH:7.5 kpts
WAVEFORM CAPTURE RATE:-
DIGITAL CHANNELS:-
Data Sheet
download UTD1000C Series Digital Oscilloscopes - Data Sheet
Version:V1.0
Release Date:2024/8/6
QuickStart Guide
User Manual
download UTD1000C Series Digital Oscilloscopes - User Manual
Version:V1.0
Release Date:2024/8/7
download UTD1000C Series Digital Oscilloscopes - User Manual (Deutsch)
Version:V1.0
Release Date:2024/10/28
download UTD1000C Series Digital Oscilloscopes - User Manual (Spanish)
Version:V1.0
Release Date:2024/12/3
Programming Manual
Service Manual
Performance Verification Guide
OPTIONS
ACCESSORIES
UT-P20
download EN
UT-P20
Description:Passive probe: (100:1) Bandwidth: 250MHz. voltage: 1500V
UT-P21
download EN
UT-P21
Description:Passive high voltage probe: (1000:1) Bandwidth: 40MHz voltage: DC 10kV/AC 7kVrms
UT-P30
download EN
UT-P30
Description:Differential probe:(10:1/100:1) Bandwidth: 100MHz differential voltage: 800Vpp
UT-P31
download EN
UT-P31
Description:High voltage differential probe: (100:1/1000:1) Bandwidth: 100MHz differential voltage: 1500Vpp
UT-P32
download EN
UT-P32
Description:Differential probe:(1000:1/100:1)Bandwidth: 50MHz Input differential voltage: 3000Vpp
UT-P33
download EN
UT-P33
Description:Differential probe:(1000:1/100:1) Bandwidth: 70/50MHz differential voltage: 14KVpp
UT-V23
download EN
UT-V23
Description:High voltage probe:(100:1)Bandwidth: 100MHz voltage: 2000Vpp
UT-P40
download EN
UT-P40
Description:Conversion ratio:50mV/A, 5mV/A, Current range : 0.4A~60A,Frequency: DC~100kHz voltage: 600Vrms
UT-P41
download EN
UT-P41
Description:Conversion ratio:100mV/A, 10mV/A, Current range: 50mA~100A Frequency: DC~100kHz, voltage: 600Vrms
UT-P43
download EN
UT-P43
Description:Current range :20A AC/DC, Frequency: DC~25MHz,Conversion ratio:100mV/A
UT-P44
download EN
UT-P44
Description:Current range: 40A AC/DC, Frequency: DC~50MHz,Conversion ratio:50mV/A
UT-L45
UT-L45
Description:BNC-BNC line :1M
UT-H03
download EN
UT-H03
Description:Probe factor:(10:1) Bandwidth: 60MHz.voltage:600Vpp
UT-H04
download EN
UT-H04
Description:Probe factor:(10:1) Bandwidth: 100MHz.voltage:600Vpp
UT-H05
download EN
UT-H05
Description:Probe factor:(10:1) Bandwidth: 200MHz.voltage:600Vpp
UT-M03
UT-M03
Description:Voltage/current converter: Range: 4mA-600mA,
UT-M04
UT-M04
Description:Voltage/current converter: Range: 4A/6A,(UTD1000C,UTD1000DL Series)
UT-P35
download EN
UT-P35
Description:High voltage Differential probe:1:50,130V(DC+peakAC); 1:500,1300V(DC+peakAC),Bandwidth:50MHz,Precision:2%
UT-P36
download EN
UT-P36
Description:High voltage Differential probe: 1/200:560(DC+peakAC) 1/2000:5600(DC+peakAC), Bandwidth:100MHz,Precision:2%
UT-P4100A
download EN
UT-P4100A
Description:100A/600kHz Low frequency current probe Range:100A/10A Freq range:DC~600kHz Rise time:≤583ns
UT-P4030D
download EN
UT-P4030D
Description:30A/ DC~100MHz High frequency current probe Range:30A/5A Freq range:DC~100MHz Rise time:≤3.5ns
UT-P4150
download EN
UT-P4150
Description:150A/ DC-12MHz High frequency current probe Range:150A/30A Freq range:DC~12MHz Rise time:≤29ns
UT-P4500
download EN
UT-P4500
Description:500A/ DC~5MHz High frequency current probe Range:500A/75A Freq range:DC~5MHz Rise time:≤70ns
UT-P4100B
download EN
UT-P4100B
Description:100A/2MHz Low frequency current probe Range:100A/10A Freq range:DC~2MHz Rise time:≤175ns
SOFTWARE
UTD1000C Software
Version: V1.00
2015/09/17
FIRMWARE
FAQs
Why the value measured by the oscilloscope is different from the value measured by the multimeter?
How does an oscilloscope measure power supply ripple?
The measurement error of oscilloscope is relatively large
Maintenace and Cleaning
Why is there no waveform output from the signal generator?
Why the signal generator cannot recognize U disk?
No screen display(blank screen)
What is the difference of real-time sampling and equivalent sampling?
What impact does a low sampling rate have on testing and measurement?
The conversion relationship between peak value(Vp), peak-to-peak value(Vpp), and RMS value(Vrms).
What is the relation of channel coupling and trigger coupling?
Why is there a significant difference in RMS voltage measurements when using the same high-voltage probe EN-48000 with a UNI-T oscilloscope compared to an Agilent oscilloscope?
In an oscilloscope, how should we understand the term ±(3% x reading+0.05div)? What does one sampling interval mean?
While measuring a signal, what is the difference between using a probe in 1x mode and 10x mode?
What is the trigger of oscilloscope?
Why choose an oscilloscope with high waveform capture rate?
What are the differences between the auto, normal, and single trigger modes?
UNI-T oscilloscope has wave record function, how long can it record?
Why is there significant waveform distortion when observing high-frequency signals?
How to solve the issue of having a waveform but unable to display it stably?
What is the trigger of oscilloscope?
What is the trigger hold off?
Why the precision is different from the standard specification?
How to use digital oscilloscope to measure radiate of switching power supply?
How to measure small signals using a digital oscilloscope? For example, small signals from an audio amplifier or power supply ripple noise.
How to measure differential signal using digital oscilloscope ?
What is Rise Time?
What is the difference of analog oscilloscope and digital oscilloscope?
Why does a 1kHz square wave measurement result in ghosting phenomenon?
Why does the instrument display normally when connected to the PC software, but none of the buttons respond?
Why is the phase difference displayed incorrectly when measuring signals with a phase difference of 180 degrees or other phase differences?
Why does a square wave signal appear as a triangle wave when measured?
Why does a square wave signal appear as a sine wave when measured?
Why does the AUTO function sometimes prompt an AUTO failure?
Is the bandwidth of oscilloscope the higher the better?
How to capture continuous waveforms of a signal over a period of time?
Release notes