UT5300+ SERIES

UT5300+ series is an instrument that integrates multiple testing functions of electrical strength (AC/DC withstand voltage) and insulation resistance. It can be widely used in the safety performance inspection of household appliances, transformers, electrical equipment and components.

1
CHANNELS
0.050kV~5.000kV
AC VOLTAGE
0.050kV~6.000kV
DC VOLTAGE
0.001mA~20mA
AC CURRENT
0.001mA~10.00mA
DC CURRENT
0.1MΩ– 10GΩ
INSULATION RESISTANCE
4.3'' TFT LCD
DISPLAY
RS232C,LAN,RS485(optional)
CONNECTIVITY
Rich interface

Rich interface

Equipped with Handler (PLC) interface for industrial control, RS485 (option), RS-232C and LAN interface for connecting to a computer. At the same time, it supports two communication protocols, SCPI and Modbus RTU, and efficiently completes the functions of remote control and data acquisition.  

IR measuremen

IR measuremen

Insulation resistance test voltage is 2.5kV as standard, 5.0kV is optional, suitable for more test occasions.  

Intelligent judgment

Intelligent judgment

Upper and lower limit intelligent judgment function, and provide sound and light alarm at the same time. Provide a good prompt for the measurement work, and broadcast the results immediately.  

File management

File management

Programmable 100 groups of test files, each group can contain 20 steps of test operations. Create favorable conditions for programmatic control of safety testing operations.  

Easy to operate

Easy to operate

With 4.3 inch LCD screen, numeric keys and function keys, it is convenient to set up, select and control the test process. The screen is large and the displayed content is specific and clear.  

Multiple test modes

Multiple test modes

Support multiple test modes, support AC, DC withstand voltage test, insulation resistance test. high accuracy and fast measurement speed

UT5310A+

CHANNELS:1
AC VOLTAGE:0.050kV~5.000kV
DC VOLTAGE:-
AC CURRENT:0.001mA~10mA
DC CURRENT:-
INSULATION RESISTANCE:-
DISPLAY:4.3'' TFT LCD
CONNECTIVITY:RS232C,RS485(optional)
Add to Compare

UT5310D+

CHANNELS:1
AC VOLTAGE:0.050kV~5.000kV
DC VOLTAGE:0.050kV~6.000kV
AC CURRENT:0.001mA~10mA
DC CURRENT:0.001mA~5.00mA
INSULATION RESISTANCE:-
DISPLAY:4.3'' TFT LCD
CONNECTIVITY:RS232C,RS485(optional)
Add to Compare

UT5310R+

CHANNELS:1
AC VOLTAGE:0.050kV~5.000kV
DC VOLTAGE:0.050kV~6.000kV
AC CURRENT:0.001mA~10mA
DC CURRENT:0.001mA~5.00mA
INSULATION RESISTANCE:0.2MΩ– 10GΩ
DISPLAY:4.3'' TFT LCD
CONNECTIVITY:RS232C,LAN,RS485(optional)
Add to Compare

UT5320R+

CHANNELS:1
AC VOLTAGE:0.050kV~5.000kV
DC VOLTAGE:0.050kV~6.000kV
AC CURRENT:0.001mA~20mA
DC CURRENT:0.001mA~10.00mA
INSULATION RESISTANCE:0.1MΩ– 10GΩ
DISPLAY:4.3'' TFT LCD
CONNECTIVITY:RS232C,LAN,RS485(optional)
Add to Compare
DATASHEETS
download

UT5300+ Datasheet

Version:V1.0
Release Date:2022.09.13
ACCESSORIES
Model
Description
Price
Manual Download
3C
3C
Power cable
High voltage red and black test clips
High voltage red and black test clips
High voltage red and black test clips
UT-L63
UT-L63
High Voltage Rod Test Lead
RS-232
RS-232
serial line
UT-F08
UT-F08
Fuse
How to measure voltage in withstand voltage test?

Confirm the test requirements of the relevant safety standards before testing.

Recommended voltage for general non-standard withstand voltage test = 1000V + 2 times the operating voltage (test time 60 seconds). For example, a product that works on 220V, the recommended test voltage is at least 1440V.

The withstand voltage test or high voltage test (HIPOT test) is a test used to verify the quality and electrical safety characteristics of products (such as UL, CE, VDE, CSA, TUV and other standards required by international safety agencies required )


What are the differences between withstand voltage test and insulated resistance test?

Insulated resistance test is to measure the resistance value between the conductor and the insulation layer. The greater the resistance value the better the insulation performance  Typically, the value of insulation impedance (IR) must not fall below a certain megohm (MΩ). The test is usually conducted with a DC voltage of 500V or 1000V and the results are measured in megohm resistance (MΩ).

The withstand voltage test is an insulation voltage test of insulation layer.  The withstand voltage value test value is determined by the actual used voltage level , but the added voltage is higher than that of the insulation impedance (IR) test. And depending on the different requirements, it can be performed at AC or DC voltage. The results are measured in milliamperes (mA) or microamperes (uA).


What are the differences between AC withstand voltage test and DC withstand voltage test?

AC withstand voltage test can perform voltage test immediately and basically no discharge is required  after the test. DC withstand voltage test can measured products with capacitive loads.